Troubleshoot invalid node registrations (INVALID_REG) in AWS PCS

When a node registers with hardware that conflicts with its configuration, Slurm sets the node state to INVALID_REG and drains it. The node's Reason field in the scontrol show node output reports the cause. The most common causes are a configured CPU topology that doesn't match the hardware, and, with GPU autodetection active, a socket layout that doesn't fit the detected GPU affinity. For additional information on how AWS PCS configures topology on each Slurm version, see Configuring hardware topology in AWS PCS.

CPU topology doesn't match the hardware

A configured socket layout that declares more resources than the node reports makes the node register with the following reason:

NodeName=my-cng-1-1 ... State=DOWN+CLOUD+DRAIN+INVALID_REG Reason=Low socket*core*thread count [slurm@2026-09-07T11:45:03]

The reason text is verbatim; the compared counts appear only in the slurmctld log at debug log level, as Node my-cng-1-1 has low socket*core*thread count (48 < 96). This means the configured Sockets and CoresPerSocket combination exceeds the node's real core count. For example, a Sockets custom setting greater than the actual number of NUMA or L3 cache domains produces a total that the hardware can't satisfy.

GPU affinity doesn't fit the socket boundaries

With GPU autodetection active, a socket layout that doesn't match the hardware makes the node register with the following reason:

Reason=gres/gpu GRES autodetected core affinity 0-23 on node my-cng-1-1 doesn't match socket boundaries. (Socket 0 is cores 0-0). Consider setting Parameters=l3cache_as_socket ...

This means the GPU is attached to a range of cores that doesn't fit inside one configured socket. It typically appears when GPU autodetection is enabled without CPU topology, so the node falls back to the default one-core-per-socket layout.

Resolution

Configure the CPU topology of the compute node group so the socket boundaries match the hardware:

  • On Slurm 25.11, set Sockets (and Parameters) in the custom Slurm settings of the compute node group.

  • On Slurm 26.05 and later, remove or correct a Sockets override that doesn't match the hardware, and let AWS PCS apply the automatic topology.

For more information, see Topology behavior by Slurm version.