Appendix – Manufacturer Module Datasheet Requirements
The following is a summary of commands and features that are listed as optional for implementation by the manufacturer. Their availability must be explicitly documented on the device datasheet:
-
EVENT! – long polling, support host communication purely over the serial interface (see 8.2.2 EVENT! time »Wait (blocking) for the next event or timeout«)
-
DIAG – command group for enhanced diagnostic and debugging purposes (see 8.3.1 DIAG {command} [optional parameters] »Perform a diagnostic command« )
-
OTW – over the wire, proprietary firmware update protocol (see 9.13.1 OTW »Enter firmware update mode« )
-
WHERE? – request module location information (see 11.1.2 WHERE? »Request location information«)
-
Workshop Wi-Fi Credentials – default Workshop connectivity credential (see 12.2.1 Workshop Default Wi-Fi Credentials (Optional))
-
BLE – command group exposing additional Bluetooth Low Energy wireless connectivity (see section 13)
Modules implementing this command group should also document in the device datasheet the following parameters:
-
MaxBLECentral – the maximum number of Central role configurations supported
-
MaxBLEGATT – the maximum number of Peripheral role configurations supported
-
MaxBLECharLen – length of the BLE characteristic buffer
-
MaxBLESubscriptions – the maximum number of subscriptions
-
-
GPIO – command group exposing I/O control for modules with digital and analog I/O expansion (see 14 GPIO control (new with v1.3) )
Modules implementing this command group should also document in the device datasheet the following parameters:
-
MaxIO – the number of I/O pins available, their physical location and DC electrical characteristics (for example, sink and source current and voltage thresholds)
-
IOMaxInt – largest integer value representation of the pin value
-
The following implementation parameters must be documented by all ExpressLink modules as part of the mandatory command set:
-
MaxExec – Maximum command execution time (<= 120 seconds)
-
MaxEvent – Depth of the Event queue
-
MaxOTARead – Maximum number of bytes that can be requested at once with an OTA READ command
-
MaxShadow – Maximum number of Shadow objects the module can handle
Additional documentation is provided in the device datasheet for the following commands:
-
SLEEP# – a list of available low power modes, their operating conditions and expected power consumption (see 4.7.4 SLEEP[#] [duration] »Request to enter a low power mode« )
-
CONNECT – a list of Hint Codes (see 4.7.2 CONNECT »Establish a connection to an AWS IoT Core Endpoint« )
-
Device Defender – list of Custom Metrics reported (see 10.1 AWS IoT Device Defender )
-
BLE EXCEPTION – list of Hint Codes (see section 8.2.1 EVENT? »Request the next event in the queue«)
-
BLE DISCOVER ERROR – list of Hint Codes (see section 13.2.1 BLE[#] DISCOVER [duration|CANCEL] »Scanning and Advertisement« )