You are viewing documentation for version 2 of the AWS SDK for Ruby. Version 3 documentation can be found here.
Class: Aws::MediaConvert::Types::AudioNormalizationSettings
- Inherits:
-
Struct
- Object
- Struct
- Aws::MediaConvert::Types::AudioNormalizationSettings
- Defined in:
- (unknown)
Overview
When passing AudioNormalizationSettings as input to an Aws::Client method, you can use a vanilla Hash:
{
algorithm: "ITU_BS_1770_1", # accepts ITU_BS_1770_1, ITU_BS_1770_2, ITU_BS_1770_3, ITU_BS_1770_4
algorithm_control: "CORRECT_AUDIO", # accepts CORRECT_AUDIO, MEASURE_ONLY
correction_gate_level: 1,
loudness_logging: "LOG", # accepts LOG, DONT_LOG
peak_calculation: "TRUE_PEAK", # accepts TRUE_PEAK, NONE
target_lkfs: 1.0,
}
Advanced audio normalization settings. Ignore these settings unless you need to comply with a loudness standard.
Returned by:
Instance Attribute Summary collapse
-
#algorithm ⇒ String
Choose one of the following audio normalization algorithms: ITU-R BS.1770-1: Ungated loudness.
-
#algorithm_control ⇒ String
When enabled the output audio is corrected using the chosen algorithm.
-
#correction_gate_level ⇒ Integer
Content measuring above this level will be corrected to the target level.
-
#loudness_logging ⇒ String
If set to LOG, log each output\'s audio track loudness to a CSV file.
-
#peak_calculation ⇒ String
If set to TRUE_PEAK, calculate and log the TruePeak for each output\'s audio track loudness.
-
#target_lkfs ⇒ Float
When you use Audio normalization (AudioNormalizationSettings), optionally use this setting to specify a target loudness.
Instance Attribute Details
#algorithm ⇒ String
Choose one of the following audio normalization algorithms: ITU-R BS.1770-1: Ungated loudness. A measurement of ungated average loudness for an entire piece of content, suitable for measurement of short-form content under ATSC recommendation A/85. Supports up to 5.1 audio channels. ITU-R BS.1770-2: Gated loudness. A measurement of gated average loudness compliant with the requirements of EBU-R128. Supports up to 5.1 audio channels. ITU-R BS.1770-3: Modified peak. The same loudness measurement algorithm as 1770-2, with an updated true peak measurement. ITU-R BS.1770-4: Higher channel count. Allows for more audio channels than the other algorithms, including configurations such as 7.1.
Possible values:
- ITU_BS_1770_1
- ITU_BS_1770_2
- ITU_BS_1770_3
- ITU_BS_1770_4
#algorithm_control ⇒ String
When enabled the output audio is corrected using the chosen algorithm. If disabled, the audio will be measured but not adjusted.
Possible values:
- CORRECT_AUDIO
- MEASURE_ONLY
#correction_gate_level ⇒ Integer
Content measuring above this level will be corrected to the target level. Content measuring below this level will not be corrected.
#loudness_logging ⇒ String
If set to LOG, log each output\'s audio track loudness to a CSV file.
Possible values:
- LOG
- DONT_LOG
#peak_calculation ⇒ String
If set to TRUE_PEAK, calculate and log the TruePeak for each output\'s audio track loudness.
Possible values:
- TRUE_PEAK
- NONE
#target_lkfs ⇒ Float
When you use Audio normalization (AudioNormalizationSettings), optionally use this setting to specify a target loudness. If you don\'t specify a value here, the encoder chooses a value for you, based on the algorithm that you choose for Algorithm (algorithm). If you choose algorithm 1770-1, the encoder will choose -24 LKFS; otherwise, the encoder will choose -23 LKFS.