UpdateGatewayCapabilityConfiguration
Updates a gateway capability configuration or defines a new capability configuration. Each gateway capability defines data sources for a gateway. A capability configuration can contain multiple data source configurations. If you define OPC-UA sources for a gateway in the AWS IoT SiteWise console, all of your OPC-UA sources are stored in one capability configuration. To list all capability configurations for a gateway, use DescribeGateway.
Request Syntax
POST /20200301/gateways/gatewayId
/capability HTTP/1.1
Content-type: application/json
{
"capabilityConfiguration": "string
",
"capabilityNamespace": "string
"
}
URI Request Parameters
The request uses the following URI parameters.
- gatewayId
-
The ID of the gateway to be updated.
Length Constraints: Fixed length of 36.
Pattern:
^[0-9a-f]{8}-[0-9a-f]{4}-[0-9a-f]{4}-[0-9a-f]{4}-[0-9a-f]{12}$
Required: Yes
Request Body
The request accepts the following data in JSON format.
- capabilityConfiguration
-
The JSON document that defines the configuration for the gateway capability. For more information, see Configuring data sources (CLI) in the AWS IoT SiteWise User Guide.
Type: String
Length Constraints: Minimum length of 1. Maximum length of 10000000.
Required: Yes
- capabilityNamespace
-
The namespace of the gateway capability configuration to be updated. For example, if you configure OPC-UA sources from the AWS IoT SiteWise console, your OPC-UA capability configuration has the namespace
iotsitewise:opcuacollector:version
, whereversion
is a number such as1
.Type: String
Length Constraints: Minimum length of 1. Maximum length of 512.
Pattern:
^[a-zA-Z]+:[a-zA-Z]+:[0-9]+$
Required: Yes
Response Syntax
HTTP/1.1 201
Content-type: application/json
{
"capabilityNamespace": "string",
"capabilitySyncStatus": "string"
}
Response Elements
If the action is successful, the service sends back an HTTP 201 response.
The following data is returned in JSON format by the service.
- capabilityNamespace
-
The namespace of the gateway capability.
Type: String
Length Constraints: Minimum length of 1. Maximum length of 512.
Pattern:
^[a-zA-Z]+:[a-zA-Z]+:[0-9]+$
- capabilitySyncStatus
-
The synchronization status of the capability configuration. The sync status can be one of the following:
-
IN_SYNC
– The gateway is running the capability configuration. -
NOT_APPLICABLE
– Synchronization is not required for this capability configuration. This is most common when integrating partner data sources, because the data integration is handled externally by the partner. -
OUT_OF_SYNC
– The gateway hasn't received the capability configuration. -
SYNC_FAILED
– The gateway rejected the capability configuration. -
UNKNOWN
– The synchronization status is currently unknown due to an undetermined or temporary error.
After you update a capability configuration, its sync status is
OUT_OF_SYNC
until the gateway receives and applies or rejects the updated configuration.Type: String
Valid Values:
IN_SYNC | OUT_OF_SYNC | SYNC_FAILED | UNKNOWN | NOT_APPLICABLE | ARCHIVED
-
Errors
For information about the errors that are common to all actions, see Common Errors.
- ConflictingOperationException
-
Your request has conflicting operations. This can occur if you're trying to perform more than one operation on the same resource at the same time.
HTTP Status Code: 409
- InternalFailureException
-
AWS IoT SiteWise can't process your request right now. Try again later.
HTTP Status Code: 500
- InvalidRequestException
-
The request isn't valid. This can occur if your request contains malformed JSON or unsupported characters. Check your request and try again.
HTTP Status Code: 400
- LimitExceededException
-
You've reached the limit for a resource. For example, this can occur if you're trying to associate more than the allowed number of child assets or attempting to create more than the allowed number of properties for an asset model.
For more information, see Quotas in the AWS IoT SiteWise User Guide.
HTTP Status Code: 410
- ResourceNotFoundException
-
The requested resource can't be found.
HTTP Status Code: 404
- ThrottlingException
-
Your request exceeded a rate limit. For example, you might have exceeded the number of AWS IoT SiteWise assets that can be created per second, the allowed number of messages per second, and so on.
For more information, see Quotas in the AWS IoT SiteWise User Guide.
HTTP Status Code: 429
See Also
For more information about using this API in one of the language-specific AWS SDKs, see the following: