AWS IoT Greengrass Version 1 entered the extended life phase on June 30, 2023. For more information, see the AWS IoT Greengrass V1 maintenance policy. After this date, AWS IoT Greengrass V1 won't release updates that provide features, enhancements, bug fixes, or security patches. Devices that run on AWS IoT Greengrass V1 won't be disrupted and will continue to operate and to connect to the cloud. We strongly recommend that you migrate to AWS IoT Greengrass Version 2, which adds significant new features and support for additional platforms.

Modbus-RTU Protocol Adapter connector

The Modbus-RTU Protocol Adapter connector polls information from Modbus RTU devices that are in the AWS IoT Greengrass group.

This connector receives parameters for a Modbus RTU request from a user-defined Lambda function. It sends the corresponding request, and then publishes the response from the target device as an MQTT message.

This connector has the following versions.

Version

ARN

3

arn:aws:greengrass:region::/connectors/ModbusRTUProtocolAdapter/versions/3

2

arn:aws:greengrass:region::/connectors/ModbusRTUProtocolAdapter/versions/2

1

arn:aws:greengrass:region::/connectors/ModbusRTUProtocolAdapter/versions/1

For information about version changes, see the Changelog.

Requirements

This connector has the following requirements:

Version 3
  • AWS IoT Greengrass Core software v1.9.3 or later.

  • Python version 3.7 or 3.8 installed on the core device and added to the PATH environment variable.

    Note

    To use Python 3.8, run the following command to create a symbolic link from the the default Python 3.7 installation folder to the installed Python 3.8 binaries.

    sudo ln -s path-to-python-3.8/python3.8 /usr/bin/python3.7

    This configures your device to meet the Python requirement for AWS IoT Greengrass.

  • A physical connection between the AWS IoT Greengrass core and the Modbus devices. The core must be physically connected to the Modbus RTU network through a serial port; for example, a USB port.

  • A local device resource in the Greengrass group that points to the physical Modbus serial port.

  • A user-defined Lambda function that sends Modbus RTU request parameters to this connector. The request parameters must conform to expected patterns and include the IDs and addresses of the target devices on the Modbus RTU network. For more information, see Input data.

Versions 1 - 2
  • AWS IoT Greengrass Core software v1.7 or later.

  • Python version 2.7 installed on the core device and added to the PATH environment variable.

  • A physical connection between the AWS IoT Greengrass core and the Modbus devices. The core must be physically connected to the Modbus RTU network through a serial port; for example, a USB port.

  • A local device resource in the Greengrass group that points to the physical Modbus serial port.

  • A user-defined Lambda function that sends Modbus RTU request parameters to this connector. The request parameters must conform to expected patterns and include the IDs and addresses of the target devices on the Modbus RTU network. For more information, see Input data.

Connector Parameters

This connector supports the following parameters:

ModbusSerialPort-ResourceId

The ID of the local device resource that represents the physical Modbus serial port.

Note

This connector is granted read-write access to the resource.

Display name in the AWS IoT console: Modbus serial port resource

Required: true

Type: string

Valid pattern: .+

ModbusSerialPort

The absolute path to the physical Modbus serial port on the device. This is the source path that's specified for the Modbus local device resource.

Display name in the AWS IoT console: Source path of Modbus serial port resource

Required: true

Type: string

Valid pattern: .+

Create Connector Example (AWS CLI)

The following CLI command creates a ConnectorDefinition with an initial version that contains the Modbus-RTU Protocol Adapter connector.

aws greengrass create-connector-definition --name MyGreengrassConnectors --initial-version '{ "Connectors": [ { "Id": "MyModbusRTUProtocolAdapterConnector", "ConnectorArn": "arn:aws:greengrass:region::/connectors/ModbusRTUProtocolAdapter/versions/3", "Parameters": { "ModbusSerialPort-ResourceId": "MyLocalModbusSerialPort", "ModbusSerialPort": "/path-to-port" } } ] }'
Note

The Lambda function in this connector has a long-lived lifecycle.

In the AWS IoT Greengrass console, you can add a connector from the group's Connectors page. For more information, see Getting started with Greengrass connectors (console).

Note

After you deploy the Modbus-RTU Protocol Adapter connector, you can use AWS IoT Things Graph to orchestrate interactions between devices in your group. For more information, see Modbus in the AWS IoT Things Graph User Guide.

Input data

This connector accepts Modbus RTU request parameters from a user-defined Lambda function on an MQTT topic. Input messages must be in JSON format.

Topic filter in subscription

modbus/adapter/request

Message properties

The request message varies based on the type of Modbus RTU request that it represents. The following properties are required for all requests:

  • In the request object:

    • operation. The name of the operation to execute. For example, specify "operation": "ReadCoilsRequest" to read coils. This value must be a Unicode string. For supported operations, see Modbus RTU requests and responses.

    • device. The target device of the request. This value must be between 0 - 247.

  • The id property. An ID for the request. This value is used for data deduplication and is returned as is in the id property of all responses, including error responses. This value must be a Unicode string.

Note

If your request includes an address field, you must specify the value as an integer. For example, "address": 1.

The other parameters to include in the request depend on the operation. All request parameters are required except the CRC, which is handled separately. For examples, see Example requests and responses.

Example input: Read coils request
{ "request": { "operation": "ReadCoilsRequest", "device": 1, "address": 1, "count": 1 }, "id": "TestRequest" }

Output data

This connector publishes responses to incoming Modbus RTU requests.

Topic filter in subscription

modbus/adapter/response

Message properties

The format of the response message varies based on the corresponding request and the response status. For examples, see Example requests and responses.

Note

A response for a write operation is simply an echo of the request. Although no meaningful information is returned for write responses, it's a good practice to check the status of the response.

Every response includes the following properties:

  • In the response object:

    • status. The status of the request. The status can be one of the following values:

      • Success. The request was valid, sent to the Modbus RTU network, and a response was returned.

      • Exception. The request was valid, sent to the Modbus RTU network, and an exception response was returned. For more information, see Response status: Exception.

      • No Response. The request was invalid, and the connector caught the error before the request was sent over the Modbus RTU network. For more information, see Response status: No response.

    • device. The device that the request was sent to.

    • operation. The request type that was sent.

    • payload. The response content that was returned. If the status is No Response, this object contains only an error property with the error description (for example, "error": "[Input/Output] No Response received from the remote unit").

  • The id property. The ID of the request, used for data deduplication.

Example output: Success
{ "response" : { "status" : "success", "device": 1, "operation": "ReadCoilsRequest", "payload": { "function_code": 1, "bits": [1] } }, "id" : "TestRequest" }
Example output: Failure
{ "response" : { "status" : "fail", "error_message": "Internal Error", "error": "Exception", "device": 1, "operation": "ReadCoilsRequest", "payload": { "function_code": 129, "exception_code": 2 } }, "id" : "TestRequest" }

For more examples, see Example requests and responses.

Modbus RTU requests and responses

This connector accepts Modbus RTU request parameters as input data and publishes responses as output data.

The following common operations are supported.

Operation name in request Function code in response
ReadCoilsRequest 01
ReadDiscreteInputsRequest 02
ReadHoldingRegistersRequest 03
ReadInputRegistersRequest 04
WriteSingleCoilRequest 05
WriteSingleRegisterRequest 06
WriteMultipleCoilsRequest 15
WriteMultipleRegistersRequest 16
MaskWriteRegisterRequest 22
ReadWriteMultipleRegistersRequest 23

The following are example requests and responses for supported operations.

Read Coils

Request example:

{ "request": { "operation": "ReadCoilsRequest", "device": 1, "address": 1, "count": 1 }, "id": "TestRequest" }

Response example:

{ "response": { "status": "success", "device": 1, "operation": "ReadCoilsRequest", "payload": { "function_code": 1, "bits": [1] } }, "id" : "TestRequest" }
Read Discrete Inputs

Request example:

{ "request": { "operation": "ReadDiscreteInputsRequest", "device": 1, "address": 1, "count": 1 }, "id": "TestRequest" }

Response example:

{ "response": { "status": "success", "device": 1, "operation": "ReadDiscreteInputsRequest", "payload": { "function_code": 2, "bits": [1] } }, "id" : "TestRequest" }
Read Holding Registers

Request example:

{ "request": { "operation": "ReadHoldingRegistersRequest", "device": 1, "address": 1, "count": 1 }, "id": "TestRequest" }

Response example:

{ "response": { "status": "success", "device": 1, "operation": "ReadHoldingRegistersRequest", "payload": { "function_code": 3, "registers": [20,30] } }, "id" : "TestRequest" }
Read Input Registers

Request example:

{ "request": { "operation": "ReadInputRegistersRequest", "device": 1, "address": 1, "value": 1 }, "id": "TestRequest" }
Write Single Coil

Request example:

{ "request": { "operation": "WriteSingleCoilRequest", "device": 1, "address": 1, "value": 1 }, "id": "TestRequest" }

Response example:

{ "response": { "status": "success", "device": 1, "operation": "WriteSingleCoilRequest", "payload": { "function_code": 5, "address": 1, "value": true } }, "id" : "TestRequest"
Write Single Register

Request example:

{ "request": { "operation": "WriteSingleRegisterRequest", "device": 1, "address": 1, "value": 1 }, "id": "TestRequest" }
Write Multiple Coils

Request example:

{ "request": { "operation": "WriteMultipleCoilsRequest", "device": 1, "address": 1, "values": [1,0,0,1] }, "id": "TestRequest" }

Response example:

{ "response": { "status": "success", "device": 1, "operation": "WriteMultipleCoilsRequest", "payload": { "function_code": 15, "address": 1, "count": 4 } }, "id" : "TestRequest" }
Write Multiple Registers

Request example:

{ "request": { "operation": "WriteMultipleRegistersRequest", "device": 1, "address": 1, "values": [20,30,10] }, "id": "TestRequest" }

Response example:

{ "response": { "status": "success", "device": 1, "operation": "WriteMultipleRegistersRequest", "payload": { "function_code": 23, "address": 1, "count": 3 } }, "id" : "TestRequest" }
Mask Write Register

Request example:

{ "request": { "operation": "MaskWriteRegisterRequest", "device": 1, "address": 1, "and_mask": 175, "or_mask": 1 }, "id": "TestRequest" }

Response example:

{ "response": { "status": "success", "device": 1, "operation": "MaskWriteRegisterRequest", "payload": { "function_code": 22, "and_mask": 0, "or_mask": 8 } }, "id" : "TestRequest" }
Read Write Multiple Registers

Request example:

{ "request": { "operation": "ReadWriteMultipleRegistersRequest", "device": 1, "read_address": 1, "read_count": 2, "write_address": 3, "write_registers": [20,30,40] }, "id": "TestRequest" }

Response example:

{ "response": { "status": "success", "device": 1, "operation": "ReadWriteMultipleRegistersRequest", "payload": { "function_code": 23, "registers": [10,20,10,20] } }, "id" : "TestRequest" }
Note

The registers returned in this response are the registers that are read from.

Exceptions can occur when the request format is valid, but the request is not completed successfully. In this case, the response contains the following information:

  • The status is set to Exception.

  • The function_code equals the function code of the request + 128.

  • The exception_code contains the exception code. For more information, see Modbus exception codes.

Example:

{ "response" : { "status" : "fail", "error_message": "Internal Error", "error": "Exception", "device": 1, "operation": "ReadCoilsRequest", "payload": { "function_code": 129, "exception_code": 2 } }, "id" : "TestRequest" }

This connector performs validation checks on the Modbus request. For example, it checks for invalid formats and missing fields. If the validation fails, the connector doesn't send the request. Instead, it returns a response that contains the following information:

  • The status is set to No Response.

  • The error contains the reason for the error.

  • The error_message contains the error message.

Examples:

{ "response" : { "status" : "fail", "error_message": "Invalid address field. Expected <type 'int'>, got <type 'str'>", "error": "No Response", "device": 1, "operation": "ReadCoilsRequest", "payload": { "error": "Invalid address field. Expected <type 'int'>, got <type 'str'>" } }, "id" : "TestRequest" }

If the request targets a nonexistent device or if the Modbus RTU network is not working, you might get a ModbusIOException, which uses the No Response format.

{ "response" : { "status" : "fail", "error_message": "[Input/Output] No Response received from the remote unit", "error": "No Response", "device": 1, "operation": "ReadCoilsRequest", "payload": { "error": "[Input/Output] No Response received from the remote unit" } }, "id" : "TestRequest" }

Usage Example

Use the following high-level steps to set up an example Python 3.7 Lambda function that you can use to try out the connector.

Note
  1. Make sure you meet the requirements for the connector.

  2. Create and publish a Lambda function that sends input data to the connector.

    Save the example code as a PY file. Download and unzip the AWS IoT Greengrass Core SDK for Python. Then, create a zip package that contains the PY file and the greengrasssdk folder at the root level. This zip package is the deployment package that you upload to AWS Lambda.

    After you create the Python 3.7 Lambda function, publish a function version and create an alias.

  3. Configure your Greengrass group.

    1. Add the Lambda function by its alias (recommended). Configure the Lambda lifecycle as long-lived (or "Pinned": true in the CLI).

    2. Add the required local device resource and grant read/write access to the Lambda function.

    3. Add the connector and configure its parameters.

    4. Add subscriptions that allow the connector to receive input data and send output data on supported topic filters.

      • Set the Lambda function as the source, the connector as the target, and use a supported input topic filter.

      • Set the connector as the source, AWS IoT Core as the target, and use a supported output topic filter. You use this subscription to view status messages in the AWS IoT console.

  4. Deploy the group.

  5. In the AWS IoT console, on the Test page, subscribe to the output data topic to view status messages from the connector. The example Lambda function is long-lived and starts sending messages immediately after the group is deployed.

    When you're finished testing, you can set the Lambda lifecycle to on-demand (or "Pinned": false in the CLI) and deploy the group. This stops the function from sending messages.

Example

The following example Lambda function sends an input message to the connector.

import greengrasssdk import json TOPIC_REQUEST = 'modbus/adapter/request' # Creating a greengrass core sdk client iot_client = greengrasssdk.client('iot-data') def create_read_coils_request(): request = { "request": { "operation": "ReadCoilsRequest", "device": 1, "address": 1, "count": 1 }, "id": "TestRequest" } return request def publish_basic_request(): iot_client.publish(payload=json.dumps(create_read_coils_request()), topic=TOPIC_REQUEST) publish_basic_request() def lambda_handler(event, context): return

Licenses

The Modbus-RTU Protocol Adapter connector includes the following third-party software/licensing:

This connector is released under the Greengrass Core Software License Agreement.

Changelog

The following table describes the changes in each version of the connector.

Version

Changes

3

Upgraded the Lambda runtime to Python 3.7, which changes the runtime requirement.

2

Updated connector ARN for AWS Region support.

Improved error logging.

1

Initial release.

A Greengrass group can contain only one version of the connector at a time. For information about upgrading a connector version, see Upgrading connector versions.