Setting up a single-pipeline channel with upgrade options

When you first create the channel, you might want to set it up without pipeline redundancy. But you might want to allow for easy upgrade to pipeline redundancy later.

Follow these guidelines when you plan the workflow:

  • When you create inputs, set up all the inputs as standard-class inputs.

    Some inputs — CDI inputs and RTP inputs — are always set up as standard-class inputs. For all other inputs, set the Input class field to Standard input.

  • When you create the channel, do the following:

  • Contact the upstream system and request that they provide one content source.

How a single-pipeline channel works

When you set up a single-pipeline channel with the option to easily upgrade, the channel is a single-pipeline channel but the inputs are all standard-class inputs.

  • The channel contains one pipeline—pipeline 0.

  • Each standard-class input contains two pipelines. However, only one of the pipelines is connected to a content source. The other input pipeline is inactive.

As this diagram illustrates, the upstream system provides one instance of the source content to the input, to the pipeline that is indicated by the blue line. The input provides that one instance to the one pipeline in the channel. The channel produces one instance of the output for the downstream system. The other pipeline in the input (the green pipeline) is always inactive.

Failure handling

If there is a problem that causes a pipeline to stop functioning, MediaLive stops producing output. The downstream system stops receiving output.