@Generated(value="com.amazonaws:aws-java-sdk-code-generator") public class UpdateSiteRackPhysicalPropertiesRequest extends AmazonWebServiceRequest implements Serializable, Cloneable
NOOP| Constructor and Description |
|---|
UpdateSiteRackPhysicalPropertiesRequest() |
| Modifier and Type | Method and Description |
|---|---|
UpdateSiteRackPhysicalPropertiesRequest |
clone()
Creates a shallow clone of this object for all fields except the handler context.
|
boolean |
equals(Object obj) |
String |
getFiberOpticCableType()
The type of fiber that you will use to attach the Outpost to your network.
|
String |
getMaximumSupportedWeightLbs()
The maximum rack weight that this site can support.
|
String |
getOpticalStandard()
The type of optical standard that you will use to attach the Outpost to your network.
|
String |
getPowerConnector()
The power connector that Amazon Web Services should plan to provide for connections to the hardware.
|
String |
getPowerDrawKva()
The power draw, in kVA, available at the hardware placement position for the rack.
|
String |
getPowerFeedDrop()
Indicates whether the power feed comes above or below the rack.
|
String |
getPowerPhase()
The power option that you can provide for hardware.
|
String |
getSiteId()
The ID or the Amazon Resource Name (ARN) of the site.
|
String |
getUplinkCount()
Racks come with two Outpost network devices.
|
String |
getUplinkGbps()
The uplink speed the rack should support for the connection to the Region.
|
int |
hashCode() |
void |
setFiberOpticCableType(String fiberOpticCableType)
The type of fiber that you will use to attach the Outpost to your network.
|
void |
setMaximumSupportedWeightLbs(String maximumSupportedWeightLbs)
The maximum rack weight that this site can support.
|
void |
setOpticalStandard(String opticalStandard)
The type of optical standard that you will use to attach the Outpost to your network.
|
void |
setPowerConnector(String powerConnector)
The power connector that Amazon Web Services should plan to provide for connections to the hardware.
|
void |
setPowerDrawKva(String powerDrawKva)
The power draw, in kVA, available at the hardware placement position for the rack.
|
void |
setPowerFeedDrop(String powerFeedDrop)
Indicates whether the power feed comes above or below the rack.
|
void |
setPowerPhase(String powerPhase)
The power option that you can provide for hardware.
|
void |
setSiteId(String siteId)
The ID or the Amazon Resource Name (ARN) of the site.
|
void |
setUplinkCount(String uplinkCount)
Racks come with two Outpost network devices.
|
void |
setUplinkGbps(String uplinkGbps)
The uplink speed the rack should support for the connection to the Region.
|
String |
toString()
Returns a string representation of this object.
|
UpdateSiteRackPhysicalPropertiesRequest |
withFiberOpticCableType(FiberOpticCableType fiberOpticCableType)
The type of fiber that you will use to attach the Outpost to your network.
|
UpdateSiteRackPhysicalPropertiesRequest |
withFiberOpticCableType(String fiberOpticCableType)
The type of fiber that you will use to attach the Outpost to your network.
|
UpdateSiteRackPhysicalPropertiesRequest |
withMaximumSupportedWeightLbs(MaximumSupportedWeightLbs maximumSupportedWeightLbs)
The maximum rack weight that this site can support.
|
UpdateSiteRackPhysicalPropertiesRequest |
withMaximumSupportedWeightLbs(String maximumSupportedWeightLbs)
The maximum rack weight that this site can support.
|
UpdateSiteRackPhysicalPropertiesRequest |
withOpticalStandard(OpticalStandard opticalStandard)
The type of optical standard that you will use to attach the Outpost to your network.
|
UpdateSiteRackPhysicalPropertiesRequest |
withOpticalStandard(String opticalStandard)
The type of optical standard that you will use to attach the Outpost to your network.
|
UpdateSiteRackPhysicalPropertiesRequest |
withPowerConnector(PowerConnector powerConnector)
The power connector that Amazon Web Services should plan to provide for connections to the hardware.
|
UpdateSiteRackPhysicalPropertiesRequest |
withPowerConnector(String powerConnector)
The power connector that Amazon Web Services should plan to provide for connections to the hardware.
|
UpdateSiteRackPhysicalPropertiesRequest |
withPowerDrawKva(PowerDrawKva powerDrawKva)
The power draw, in kVA, available at the hardware placement position for the rack.
|
UpdateSiteRackPhysicalPropertiesRequest |
withPowerDrawKva(String powerDrawKva)
The power draw, in kVA, available at the hardware placement position for the rack.
|
UpdateSiteRackPhysicalPropertiesRequest |
withPowerFeedDrop(PowerFeedDrop powerFeedDrop)
Indicates whether the power feed comes above or below the rack.
|
UpdateSiteRackPhysicalPropertiesRequest |
withPowerFeedDrop(String powerFeedDrop)
Indicates whether the power feed comes above or below the rack.
|
UpdateSiteRackPhysicalPropertiesRequest |
withPowerPhase(PowerPhase powerPhase)
The power option that you can provide for hardware.
|
UpdateSiteRackPhysicalPropertiesRequest |
withPowerPhase(String powerPhase)
The power option that you can provide for hardware.
|
UpdateSiteRackPhysicalPropertiesRequest |
withSiteId(String siteId)
The ID or the Amazon Resource Name (ARN) of the site.
|
UpdateSiteRackPhysicalPropertiesRequest |
withUplinkCount(String uplinkCount)
Racks come with two Outpost network devices.
|
UpdateSiteRackPhysicalPropertiesRequest |
withUplinkCount(UplinkCount uplinkCount)
Racks come with two Outpost network devices.
|
UpdateSiteRackPhysicalPropertiesRequest |
withUplinkGbps(String uplinkGbps)
The uplink speed the rack should support for the connection to the Region.
|
UpdateSiteRackPhysicalPropertiesRequest |
withUplinkGbps(UplinkGbps uplinkGbps)
The uplink speed the rack should support for the connection to the Region.
|
addHandlerContext, getCloneRoot, getCloneSource, getCustomQueryParameters, getCustomRequestHeaders, getGeneralProgressListener, getHandlerContext, getReadLimit, getRequestClientOptions, getRequestCredentials, getRequestCredentialsProvider, getRequestMetricCollector, getSdkClientExecutionTimeout, getSdkRequestTimeout, putCustomQueryParameter, putCustomRequestHeader, setGeneralProgressListener, setRequestCredentials, setRequestCredentialsProvider, setRequestMetricCollector, setSdkClientExecutionTimeout, setSdkRequestTimeout, withGeneralProgressListener, withRequestCredentialsProvider, withRequestMetricCollector, withSdkClientExecutionTimeout, withSdkRequestTimeoutpublic UpdateSiteRackPhysicalPropertiesRequest()
public void setSiteId(String siteId)
The ID or the Amazon Resource Name (ARN) of the site.
siteId - The ID or the Amazon Resource Name (ARN) of the site.public String getSiteId()
The ID or the Amazon Resource Name (ARN) of the site.
public UpdateSiteRackPhysicalPropertiesRequest withSiteId(String siteId)
The ID or the Amazon Resource Name (ARN) of the site.
siteId - The ID or the Amazon Resource Name (ARN) of the site.public void setPowerDrawKva(String powerDrawKva)
The power draw, in kVA, available at the hardware placement position for the rack.
powerDrawKva - The power draw, in kVA, available at the hardware placement position for the rack.PowerDrawKvapublic String getPowerDrawKva()
The power draw, in kVA, available at the hardware placement position for the rack.
PowerDrawKvapublic UpdateSiteRackPhysicalPropertiesRequest withPowerDrawKva(String powerDrawKva)
The power draw, in kVA, available at the hardware placement position for the rack.
powerDrawKva - The power draw, in kVA, available at the hardware placement position for the rack.PowerDrawKvapublic UpdateSiteRackPhysicalPropertiesRequest withPowerDrawKva(PowerDrawKva powerDrawKva)
The power draw, in kVA, available at the hardware placement position for the rack.
powerDrawKva - The power draw, in kVA, available at the hardware placement position for the rack.PowerDrawKvapublic void setPowerPhase(String powerPhase)
The power option that you can provide for hardware.
Single-phase AC feed: 200 V to 277 V, 50 Hz or 60 Hz
Three-phase AC feed: 346 V to 480 V, 50 Hz or 60 Hz
powerPhase - The power option that you can provide for hardware.
Single-phase AC feed: 200 V to 277 V, 50 Hz or 60 Hz
Three-phase AC feed: 346 V to 480 V, 50 Hz or 60 Hz
PowerPhasepublic String getPowerPhase()
The power option that you can provide for hardware.
Single-phase AC feed: 200 V to 277 V, 50 Hz or 60 Hz
Three-phase AC feed: 346 V to 480 V, 50 Hz or 60 Hz
Single-phase AC feed: 200 V to 277 V, 50 Hz or 60 Hz
Three-phase AC feed: 346 V to 480 V, 50 Hz or 60 Hz
PowerPhasepublic UpdateSiteRackPhysicalPropertiesRequest withPowerPhase(String powerPhase)
The power option that you can provide for hardware.
Single-phase AC feed: 200 V to 277 V, 50 Hz or 60 Hz
Three-phase AC feed: 346 V to 480 V, 50 Hz or 60 Hz
powerPhase - The power option that you can provide for hardware.
Single-phase AC feed: 200 V to 277 V, 50 Hz or 60 Hz
Three-phase AC feed: 346 V to 480 V, 50 Hz or 60 Hz
PowerPhasepublic UpdateSiteRackPhysicalPropertiesRequest withPowerPhase(PowerPhase powerPhase)
The power option that you can provide for hardware.
Single-phase AC feed: 200 V to 277 V, 50 Hz or 60 Hz
Three-phase AC feed: 346 V to 480 V, 50 Hz or 60 Hz
powerPhase - The power option that you can provide for hardware.
Single-phase AC feed: 200 V to 277 V, 50 Hz or 60 Hz
Three-phase AC feed: 346 V to 480 V, 50 Hz or 60 Hz
PowerPhasepublic void setPowerConnector(String powerConnector)
The power connector that Amazon Web Services should plan to provide for connections to the hardware. Note the
correlation between PowerPhase and PowerConnector.
Single-phase AC feed
L6-30P – (common in US); 30A; single phase
IEC309 (blue) – P+N+E, 6hr; 32 A; single phase
Three-phase AC feed
AH530P7W (red) – 3P+N+E, 7hr; 30A; three phase
AH532P6W (red) – 3P+N+E, 6hr; 32A; three phase
powerConnector - The power connector that Amazon Web Services should plan to provide for connections to the hardware. Note
the correlation between PowerPhase and PowerConnector.
Single-phase AC feed
L6-30P – (common in US); 30A; single phase
IEC309 (blue) – P+N+E, 6hr; 32 A; single phase
Three-phase AC feed
AH530P7W (red) – 3P+N+E, 7hr; 30A; three phase
AH532P6W (red) – 3P+N+E, 6hr; 32A; three phase
PowerConnectorpublic String getPowerConnector()
The power connector that Amazon Web Services should plan to provide for connections to the hardware. Note the
correlation between PowerPhase and PowerConnector.
Single-phase AC feed
L6-30P – (common in US); 30A; single phase
IEC309 (blue) – P+N+E, 6hr; 32 A; single phase
Three-phase AC feed
AH530P7W (red) – 3P+N+E, 7hr; 30A; three phase
AH532P6W (red) – 3P+N+E, 6hr; 32A; three phase
PowerPhase and PowerConnector.
Single-phase AC feed
L6-30P – (common in US); 30A; single phase
IEC309 (blue) – P+N+E, 6hr; 32 A; single phase
Three-phase AC feed
AH530P7W (red) – 3P+N+E, 7hr; 30A; three phase
AH532P6W (red) – 3P+N+E, 6hr; 32A; three phase
PowerConnectorpublic UpdateSiteRackPhysicalPropertiesRequest withPowerConnector(String powerConnector)
The power connector that Amazon Web Services should plan to provide for connections to the hardware. Note the
correlation between PowerPhase and PowerConnector.
Single-phase AC feed
L6-30P – (common in US); 30A; single phase
IEC309 (blue) – P+N+E, 6hr; 32 A; single phase
Three-phase AC feed
AH530P7W (red) – 3P+N+E, 7hr; 30A; three phase
AH532P6W (red) – 3P+N+E, 6hr; 32A; three phase
powerConnector - The power connector that Amazon Web Services should plan to provide for connections to the hardware. Note
the correlation between PowerPhase and PowerConnector.
Single-phase AC feed
L6-30P – (common in US); 30A; single phase
IEC309 (blue) – P+N+E, 6hr; 32 A; single phase
Three-phase AC feed
AH530P7W (red) – 3P+N+E, 7hr; 30A; three phase
AH532P6W (red) – 3P+N+E, 6hr; 32A; three phase
PowerConnectorpublic UpdateSiteRackPhysicalPropertiesRequest withPowerConnector(PowerConnector powerConnector)
The power connector that Amazon Web Services should plan to provide for connections to the hardware. Note the
correlation between PowerPhase and PowerConnector.
Single-phase AC feed
L6-30P – (common in US); 30A; single phase
IEC309 (blue) – P+N+E, 6hr; 32 A; single phase
Three-phase AC feed
AH530P7W (red) – 3P+N+E, 7hr; 30A; three phase
AH532P6W (red) – 3P+N+E, 6hr; 32A; three phase
powerConnector - The power connector that Amazon Web Services should plan to provide for connections to the hardware. Note
the correlation between PowerPhase and PowerConnector.
Single-phase AC feed
L6-30P – (common in US); 30A; single phase
IEC309 (blue) – P+N+E, 6hr; 32 A; single phase
Three-phase AC feed
AH530P7W (red) – 3P+N+E, 7hr; 30A; three phase
AH532P6W (red) – 3P+N+E, 6hr; 32A; three phase
PowerConnectorpublic void setPowerFeedDrop(String powerFeedDrop)
Indicates whether the power feed comes above or below the rack.
powerFeedDrop - Indicates whether the power feed comes above or below the rack.PowerFeedDroppublic String getPowerFeedDrop()
Indicates whether the power feed comes above or below the rack.
PowerFeedDroppublic UpdateSiteRackPhysicalPropertiesRequest withPowerFeedDrop(String powerFeedDrop)
Indicates whether the power feed comes above or below the rack.
powerFeedDrop - Indicates whether the power feed comes above or below the rack.PowerFeedDroppublic UpdateSiteRackPhysicalPropertiesRequest withPowerFeedDrop(PowerFeedDrop powerFeedDrop)
Indicates whether the power feed comes above or below the rack.
powerFeedDrop - Indicates whether the power feed comes above or below the rack.PowerFeedDroppublic void setUplinkGbps(String uplinkGbps)
The uplink speed the rack should support for the connection to the Region.
uplinkGbps - The uplink speed the rack should support for the connection to the Region.UplinkGbpspublic String getUplinkGbps()
The uplink speed the rack should support for the connection to the Region.
UplinkGbpspublic UpdateSiteRackPhysicalPropertiesRequest withUplinkGbps(String uplinkGbps)
The uplink speed the rack should support for the connection to the Region.
uplinkGbps - The uplink speed the rack should support for the connection to the Region.UplinkGbpspublic UpdateSiteRackPhysicalPropertiesRequest withUplinkGbps(UplinkGbps uplinkGbps)
The uplink speed the rack should support for the connection to the Region.
uplinkGbps - The uplink speed the rack should support for the connection to the Region.UplinkGbpspublic void setUplinkCount(String uplinkCount)
Racks come with two Outpost network devices. Depending on the supported uplink speed at the site, the Outpost
network devices provide a variable number of uplinks. Specify the number of uplinks for each Outpost network
device that you intend to use to connect the rack to your network. Note the correlation between
UplinkGbps and UplinkCount.
1Gbps - Uplinks available: 1, 2, 4, 6, 8
10Gbps - Uplinks available: 1, 2, 4, 8, 12, 16
40 and 100 Gbps- Uplinks available: 1, 2, 4
uplinkCount - Racks come with two Outpost network devices. Depending on the supported uplink speed at the site, the
Outpost network devices provide a variable number of uplinks. Specify the number of uplinks for each
Outpost network device that you intend to use to connect the rack to your network. Note the correlation
between UplinkGbps and UplinkCount.
1Gbps - Uplinks available: 1, 2, 4, 6, 8
10Gbps - Uplinks available: 1, 2, 4, 8, 12, 16
40 and 100 Gbps- Uplinks available: 1, 2, 4
UplinkCountpublic String getUplinkCount()
Racks come with two Outpost network devices. Depending on the supported uplink speed at the site, the Outpost
network devices provide a variable number of uplinks. Specify the number of uplinks for each Outpost network
device that you intend to use to connect the rack to your network. Note the correlation between
UplinkGbps and UplinkCount.
1Gbps - Uplinks available: 1, 2, 4, 6, 8
10Gbps - Uplinks available: 1, 2, 4, 8, 12, 16
40 and 100 Gbps- Uplinks available: 1, 2, 4
UplinkGbps and UplinkCount.
1Gbps - Uplinks available: 1, 2, 4, 6, 8
10Gbps - Uplinks available: 1, 2, 4, 8, 12, 16
40 and 100 Gbps- Uplinks available: 1, 2, 4
UplinkCountpublic UpdateSiteRackPhysicalPropertiesRequest withUplinkCount(String uplinkCount)
Racks come with two Outpost network devices. Depending on the supported uplink speed at the site, the Outpost
network devices provide a variable number of uplinks. Specify the number of uplinks for each Outpost network
device that you intend to use to connect the rack to your network. Note the correlation between
UplinkGbps and UplinkCount.
1Gbps - Uplinks available: 1, 2, 4, 6, 8
10Gbps - Uplinks available: 1, 2, 4, 8, 12, 16
40 and 100 Gbps- Uplinks available: 1, 2, 4
uplinkCount - Racks come with two Outpost network devices. Depending on the supported uplink speed at the site, the
Outpost network devices provide a variable number of uplinks. Specify the number of uplinks for each
Outpost network device that you intend to use to connect the rack to your network. Note the correlation
between UplinkGbps and UplinkCount.
1Gbps - Uplinks available: 1, 2, 4, 6, 8
10Gbps - Uplinks available: 1, 2, 4, 8, 12, 16
40 and 100 Gbps- Uplinks available: 1, 2, 4
UplinkCountpublic UpdateSiteRackPhysicalPropertiesRequest withUplinkCount(UplinkCount uplinkCount)
Racks come with two Outpost network devices. Depending on the supported uplink speed at the site, the Outpost
network devices provide a variable number of uplinks. Specify the number of uplinks for each Outpost network
device that you intend to use to connect the rack to your network. Note the correlation between
UplinkGbps and UplinkCount.
1Gbps - Uplinks available: 1, 2, 4, 6, 8
10Gbps - Uplinks available: 1, 2, 4, 8, 12, 16
40 and 100 Gbps- Uplinks available: 1, 2, 4
uplinkCount - Racks come with two Outpost network devices. Depending on the supported uplink speed at the site, the
Outpost network devices provide a variable number of uplinks. Specify the number of uplinks for each
Outpost network device that you intend to use to connect the rack to your network. Note the correlation
between UplinkGbps and UplinkCount.
1Gbps - Uplinks available: 1, 2, 4, 6, 8
10Gbps - Uplinks available: 1, 2, 4, 8, 12, 16
40 and 100 Gbps- Uplinks available: 1, 2, 4
UplinkCountpublic void setFiberOpticCableType(String fiberOpticCableType)
The type of fiber that you will use to attach the Outpost to your network.
fiberOpticCableType - The type of fiber that you will use to attach the Outpost to your network.FiberOpticCableTypepublic String getFiberOpticCableType()
The type of fiber that you will use to attach the Outpost to your network.
FiberOpticCableTypepublic UpdateSiteRackPhysicalPropertiesRequest withFiberOpticCableType(String fiberOpticCableType)
The type of fiber that you will use to attach the Outpost to your network.
fiberOpticCableType - The type of fiber that you will use to attach the Outpost to your network.FiberOpticCableTypepublic UpdateSiteRackPhysicalPropertiesRequest withFiberOpticCableType(FiberOpticCableType fiberOpticCableType)
The type of fiber that you will use to attach the Outpost to your network.
fiberOpticCableType - The type of fiber that you will use to attach the Outpost to your network.FiberOpticCableTypepublic void setOpticalStandard(String opticalStandard)
The type of optical standard that you will use to attach the Outpost to your network. This field is dependent on uplink speed, fiber type, and distance to the upstream device. For more information about networking requirements for racks, see Network in the Amazon Web Services Outposts User Guide.
OPTIC_10GBASE_SR: 10GBASE-SR
OPTIC_10GBASE_IR: 10GBASE-IR
OPTIC_10GBASE_LR: 10GBASE-LR
OPTIC_40GBASE_SR: 40GBASE-SR
OPTIC_40GBASE_ESR: 40GBASE-ESR
OPTIC_40GBASE_IR4_LR4L: 40GBASE-IR (LR4L)
OPTIC_40GBASE_LR4: 40GBASE-LR4
OPTIC_100GBASE_SR4: 100GBASE-SR4
OPTIC_100GBASE_CWDM4: 100GBASE-CWDM4
OPTIC_100GBASE_LR4: 100GBASE-LR4
OPTIC_100G_PSM4_MSA: 100G PSM4 MSA
OPTIC_1000BASE_LX: 1000Base-LX
OPTIC_1000BASE_SX : 1000Base-SX
opticalStandard - The type of optical standard that you will use to attach the Outpost to your network. This field is
dependent on uplink speed, fiber type, and distance to the upstream device. For more information about
networking requirements for racks, see Network in the Amazon Web Services Outposts User Guide.
OPTIC_10GBASE_SR: 10GBASE-SR
OPTIC_10GBASE_IR: 10GBASE-IR
OPTIC_10GBASE_LR: 10GBASE-LR
OPTIC_40GBASE_SR: 40GBASE-SR
OPTIC_40GBASE_ESR: 40GBASE-ESR
OPTIC_40GBASE_IR4_LR4L: 40GBASE-IR (LR4L)
OPTIC_40GBASE_LR4: 40GBASE-LR4
OPTIC_100GBASE_SR4: 100GBASE-SR4
OPTIC_100GBASE_CWDM4: 100GBASE-CWDM4
OPTIC_100GBASE_LR4: 100GBASE-LR4
OPTIC_100G_PSM4_MSA: 100G PSM4 MSA
OPTIC_1000BASE_LX: 1000Base-LX
OPTIC_1000BASE_SX : 1000Base-SX
OpticalStandardpublic String getOpticalStandard()
The type of optical standard that you will use to attach the Outpost to your network. This field is dependent on uplink speed, fiber type, and distance to the upstream device. For more information about networking requirements for racks, see Network in the Amazon Web Services Outposts User Guide.
OPTIC_10GBASE_SR: 10GBASE-SR
OPTIC_10GBASE_IR: 10GBASE-IR
OPTIC_10GBASE_LR: 10GBASE-LR
OPTIC_40GBASE_SR: 40GBASE-SR
OPTIC_40GBASE_ESR: 40GBASE-ESR
OPTIC_40GBASE_IR4_LR4L: 40GBASE-IR (LR4L)
OPTIC_40GBASE_LR4: 40GBASE-LR4
OPTIC_100GBASE_SR4: 100GBASE-SR4
OPTIC_100GBASE_CWDM4: 100GBASE-CWDM4
OPTIC_100GBASE_LR4: 100GBASE-LR4
OPTIC_100G_PSM4_MSA: 100G PSM4 MSA
OPTIC_1000BASE_LX: 1000Base-LX
OPTIC_1000BASE_SX : 1000Base-SX
OPTIC_10GBASE_SR: 10GBASE-SR
OPTIC_10GBASE_IR: 10GBASE-IR
OPTIC_10GBASE_LR: 10GBASE-LR
OPTIC_40GBASE_SR: 40GBASE-SR
OPTIC_40GBASE_ESR: 40GBASE-ESR
OPTIC_40GBASE_IR4_LR4L: 40GBASE-IR (LR4L)
OPTIC_40GBASE_LR4: 40GBASE-LR4
OPTIC_100GBASE_SR4: 100GBASE-SR4
OPTIC_100GBASE_CWDM4: 100GBASE-CWDM4
OPTIC_100GBASE_LR4: 100GBASE-LR4
OPTIC_100G_PSM4_MSA: 100G PSM4 MSA
OPTIC_1000BASE_LX: 1000Base-LX
OPTIC_1000BASE_SX : 1000Base-SX
OpticalStandardpublic UpdateSiteRackPhysicalPropertiesRequest withOpticalStandard(String opticalStandard)
The type of optical standard that you will use to attach the Outpost to your network. This field is dependent on uplink speed, fiber type, and distance to the upstream device. For more information about networking requirements for racks, see Network in the Amazon Web Services Outposts User Guide.
OPTIC_10GBASE_SR: 10GBASE-SR
OPTIC_10GBASE_IR: 10GBASE-IR
OPTIC_10GBASE_LR: 10GBASE-LR
OPTIC_40GBASE_SR: 40GBASE-SR
OPTIC_40GBASE_ESR: 40GBASE-ESR
OPTIC_40GBASE_IR4_LR4L: 40GBASE-IR (LR4L)
OPTIC_40GBASE_LR4: 40GBASE-LR4
OPTIC_100GBASE_SR4: 100GBASE-SR4
OPTIC_100GBASE_CWDM4: 100GBASE-CWDM4
OPTIC_100GBASE_LR4: 100GBASE-LR4
OPTIC_100G_PSM4_MSA: 100G PSM4 MSA
OPTIC_1000BASE_LX: 1000Base-LX
OPTIC_1000BASE_SX : 1000Base-SX
opticalStandard - The type of optical standard that you will use to attach the Outpost to your network. This field is
dependent on uplink speed, fiber type, and distance to the upstream device. For more information about
networking requirements for racks, see Network in the Amazon Web Services Outposts User Guide.
OPTIC_10GBASE_SR: 10GBASE-SR
OPTIC_10GBASE_IR: 10GBASE-IR
OPTIC_10GBASE_LR: 10GBASE-LR
OPTIC_40GBASE_SR: 40GBASE-SR
OPTIC_40GBASE_ESR: 40GBASE-ESR
OPTIC_40GBASE_IR4_LR4L: 40GBASE-IR (LR4L)
OPTIC_40GBASE_LR4: 40GBASE-LR4
OPTIC_100GBASE_SR4: 100GBASE-SR4
OPTIC_100GBASE_CWDM4: 100GBASE-CWDM4
OPTIC_100GBASE_LR4: 100GBASE-LR4
OPTIC_100G_PSM4_MSA: 100G PSM4 MSA
OPTIC_1000BASE_LX: 1000Base-LX
OPTIC_1000BASE_SX : 1000Base-SX
OpticalStandardpublic UpdateSiteRackPhysicalPropertiesRequest withOpticalStandard(OpticalStandard opticalStandard)
The type of optical standard that you will use to attach the Outpost to your network. This field is dependent on uplink speed, fiber type, and distance to the upstream device. For more information about networking requirements for racks, see Network in the Amazon Web Services Outposts User Guide.
OPTIC_10GBASE_SR: 10GBASE-SR
OPTIC_10GBASE_IR: 10GBASE-IR
OPTIC_10GBASE_LR: 10GBASE-LR
OPTIC_40GBASE_SR: 40GBASE-SR
OPTIC_40GBASE_ESR: 40GBASE-ESR
OPTIC_40GBASE_IR4_LR4L: 40GBASE-IR (LR4L)
OPTIC_40GBASE_LR4: 40GBASE-LR4
OPTIC_100GBASE_SR4: 100GBASE-SR4
OPTIC_100GBASE_CWDM4: 100GBASE-CWDM4
OPTIC_100GBASE_LR4: 100GBASE-LR4
OPTIC_100G_PSM4_MSA: 100G PSM4 MSA
OPTIC_1000BASE_LX: 1000Base-LX
OPTIC_1000BASE_SX : 1000Base-SX
opticalStandard - The type of optical standard that you will use to attach the Outpost to your network. This field is
dependent on uplink speed, fiber type, and distance to the upstream device. For more information about
networking requirements for racks, see Network in the Amazon Web Services Outposts User Guide.
OPTIC_10GBASE_SR: 10GBASE-SR
OPTIC_10GBASE_IR: 10GBASE-IR
OPTIC_10GBASE_LR: 10GBASE-LR
OPTIC_40GBASE_SR: 40GBASE-SR
OPTIC_40GBASE_ESR: 40GBASE-ESR
OPTIC_40GBASE_IR4_LR4L: 40GBASE-IR (LR4L)
OPTIC_40GBASE_LR4: 40GBASE-LR4
OPTIC_100GBASE_SR4: 100GBASE-SR4
OPTIC_100GBASE_CWDM4: 100GBASE-CWDM4
OPTIC_100GBASE_LR4: 100GBASE-LR4
OPTIC_100G_PSM4_MSA: 100G PSM4 MSA
OPTIC_1000BASE_LX: 1000Base-LX
OPTIC_1000BASE_SX : 1000Base-SX
OpticalStandardpublic void setMaximumSupportedWeightLbs(String maximumSupportedWeightLbs)
The maximum rack weight that this site can support. NO_LIMIT is over 2000lbs.
maximumSupportedWeightLbs - The maximum rack weight that this site can support. NO_LIMIT is over 2000lbs.MaximumSupportedWeightLbspublic String getMaximumSupportedWeightLbs()
The maximum rack weight that this site can support. NO_LIMIT is over 2000lbs.
NO_LIMIT is over 2000lbs.MaximumSupportedWeightLbspublic UpdateSiteRackPhysicalPropertiesRequest withMaximumSupportedWeightLbs(String maximumSupportedWeightLbs)
The maximum rack weight that this site can support. NO_LIMIT is over 2000lbs.
maximumSupportedWeightLbs - The maximum rack weight that this site can support. NO_LIMIT is over 2000lbs.MaximumSupportedWeightLbspublic UpdateSiteRackPhysicalPropertiesRequest withMaximumSupportedWeightLbs(MaximumSupportedWeightLbs maximumSupportedWeightLbs)
The maximum rack weight that this site can support. NO_LIMIT is over 2000lbs.
maximumSupportedWeightLbs - The maximum rack weight that this site can support. NO_LIMIT is over 2000lbs.MaximumSupportedWeightLbspublic String toString()
toString in class ObjectObject.toString()public UpdateSiteRackPhysicalPropertiesRequest clone()
AmazonWebServiceRequestclone in class AmazonWebServiceRequestObject.clone()