Skip to content

/AWS1/CL_MDCESAMSETTINGS

Settings for Event Signaling And Messaging (ESAM). If you don't do ad insertion, you can ignore these settings.

CONSTRUCTOR

IMPORTING

Optional arguments:

IO_MANIFESTCONFIRMCONDNOTIF TYPE REF TO /AWS1/CL_MDCESAMMANIFESTCONF00 /AWS1/CL_MDCESAMMANIFESTCONF00

Specifies an ESAM ManifestConfirmConditionNotification XML as per OC-SP-ESAM-API-I03-131025. The transcoder uses the manifest conditioning instructions that you provide in the setting MCC XML.

IV_RESPONSESIGNALPREROLL TYPE /AWS1/MDC__INTEGERMIN0MAX30000 /AWS1/MDC__INTEGERMIN0MAX30000

Specifies the stream distance, in milliseconds, between the SCTE 35 messages that the transcoder places and the splice points that they refer to. If the time between the start of the asset and the SCTE-35 message is less than this value, then the transcoder places the SCTE-35 marker at the beginning of the stream.

IO_SIGNALPROCESSINGNOTIF TYPE REF TO /AWS1/CL_MDCESAMSIGNALPROCIN00 /AWS1/CL_MDCESAMSIGNALPROCIN00

Specifies an ESAM SignalProcessingNotification XML as per OC-SP-ESAM-API-I03-131025. The transcoder uses the signal processing instructions that you provide in the setting SCC XML.


Queryable Attributes

ManifestConfirmConditionNotification

Specifies an ESAM ManifestConfirmConditionNotification XML as per OC-SP-ESAM-API-I03-131025. The transcoder uses the manifest conditioning instructions that you provide in the setting MCC XML.

Accessible with the following methods

Method Description
GET_MANIFESTCONFIRMCONDNOTIF() Getter for MANIFESTCONFIRMCONDNOTIF

ResponseSignalPreroll

Specifies the stream distance, in milliseconds, between the SCTE 35 messages that the transcoder places and the splice points that they refer to. If the time between the start of the asset and the SCTE-35 message is less than this value, then the transcoder places the SCTE-35 marker at the beginning of the stream.

Accessible with the following methods

Method Description
GET_RESPONSESIGNALPREROLL() Getter for RESPONSESIGNALPREROLL, with configurable default
ASK_RESPONSESIGNALPREROLL() Getter for RESPONSESIGNALPREROLL w/ exceptions if field has
HAS_RESPONSESIGNALPREROLL() Determine if RESPONSESIGNALPREROLL has a value

SignalProcessingNotification

Specifies an ESAM SignalProcessingNotification XML as per OC-SP-ESAM-API-I03-131025. The transcoder uses the signal processing instructions that you provide in the setting SCC XML.

Accessible with the following methods

Method Description
GET_SIGNALPROCESSINGNOTIF() Getter for SIGNALPROCESSINGNOTIFICATION